MCN Remote Comparator Display (MCNRCD) Software: Standard, Server and Client Editions
How MCNRCD software shows comparator and I/O status on a PC, with its Standard, Server and Client editions, screens and error logging.
The MCN Remote Comparator Display (MCNRCD) software is the PC half of the MCN comparator display system. It shows which receivers are receiving, voted, disabled, failed or in error, lets the operator force-vote or disable receivers, and logs failures. It talks to the MCN network through a user-interface module such as an HIB.
Two programs
The original package consists of two programs, and later Windows editions keep the same split:
- A configuration program (MCNCFG, now MCN Config) run by an engineer or technician to build the configuration when the system is installed or changed.
- A runtime display program (MCNRCD) run by a dispatcher or technician to watch and control the voting system.
A text configuration file lets an engineer change several option parameters of the runtime program.
What the display shows
A receiver screen lists receiver names with an indicator for each: no activity (blue in the original), Vote (green), Receiving (light gray), Disabled (yellow), Failed (red) and Error (brown). The status text and colors can be customized at installation. In the original program up to 88 receivers fit on one screen and up to 50 screens can be created. General-purpose I/O devices (door alarms, generator run inputs, equipment failure inputs, relay outputs, transmitter main/standby controls) can be monitored on CIB or IOB modules, with their own status wording ("On/Off/Fail" instead of Vote, Receive, Disable, Fail) set up through status text categories and sub-categories.
Configuring screens
Configuration is a two-step process: first, for each group of comparator I/O modules, enter receiver names, channel names and comments; second, build the screens by entering channel titles and placing the receivers by "point and shoot". In the original DOS program the files were Group Configuration (.GCF) and Screen (.MSF) files, with one screen file able to combine four groups. In the Windows editions, configuration is organized as resource windows (network interfaces, hardware, channels, receivers) and display windows (the status screens). Different display windows can show different subsets of channels to different dispatchers, and technician screens can show more detail than dispatcher screens. Master/sub (zone) comparator systems can be represented as a "virtual comparator" on a display window.
Controlling receivers
Receivers can be force-voted to listen to their audio quality, and a defective receiver or one with a bad phone line can be disabled and later re-enabled, with mouse or keyboard. The software provides a latched disable (a second click re-enables).
Error logging
The software logs whenever a receiver fails or becomes disabled and when it returns to normal. Entries carry a time and date, the receiver status, the group, module and receiver number, the name and the comments, and can go to the screen, a disk file and a printer. Logging is available only while the PC is connected to the MCN system, so nothing is logged while it is off-line. The format can be customized with an error-logging definition file.
Editions of the software
| Edition | Characteristics (from the manuals) |
|---|---|
| MCN Standard | Runs on one PC with one network interface (an HIB-IP, HIB-232 serial module, or a PCLTA card). No remote clients and no third-party clients; no software key is required |
| MCN Server and MCN Advanced Server | Add a server program that passes status and control to MCN Client programs on other PCs over an IP LAN or WAN, so the client PCs need no MCN network interface. They use a hardware key and a software key that sets the licensed capabilities. The Advanced Server supports multiple network interfaces (four HIB-IP units, expandable) |
| MCN Server 8000 | The Advanced Server plus direct IP connections to Motorola IP comparators; see mcn-server-8000-and-ip-modules |
A Windows-based client can be a stand-alone PC and, in Motorola systems, a console PC running the client program. Support for newer modules has been added over time; for example the HIB-IP 8002 requires software version 7.20 or later. The older PC network interface cards (PCLTA) work only with 32-bit Windows because no 64-bit drivers exist.
Add-on software extends the server editions: the System Performance Toolkit and the Base Radio Status Concentrator. Hardware requirements are listed in the manuals; for example the Standard manual specifies a Windows PC with at least 2 GB memory, an 800 by 600 color monitor, a mouse and a 100Base-T port, plus a serial port or PCI slot when the interface needs one.
Source documents
This article summarizes the following published CTI Products manuals. They are the authoritative reference.
This article is part of the CTI Products Knowledge Base. Questions about RadioPro or MCN products? Call +1 (513) 595-5900 or email info@ctiproducts.com.
Informational only. This article is general background and is not engineering, safety, legal or regulatory advice. Verify requirements with the equipment manufacturer and the applicable authority before relying on it. Product names and trademarks belong to their respective owners.