Troubleshooting MCN Modules: LEDs, Buttons and Common Problems

MCN and BRSC Monitoring · Last updated · About 3 min read

What the PWR, ACT and ERR LEDs on MCN modules mean, what the reset button does, and the checks for display and control problems in an MCN comparator display system.

This article gathers the diagnostic guidance in the MCN system manual. Installation is described in mcn-installation-addressing-cabling-and-power.

Normal indications

Every MCN module has three front-panel LEDs:

LED Meaning
PWR On when the DC input voltage is within specification. It blinks if the input falls below the minimum; the module may still work, but this is not recommended
ERR On to indicate module errors (each hardware manual lists its error conditions)
ACT On or blinking when the module is communicating successfully with other modules on the network

During normal operation PWR is on, ACT is on or blinking and ERR is off. An HIB's ACT LED blinks only if a PC running the display software has a screen configuration loaded.

Every module has a RESET button that makes it re-read its configuration switches and begin communicating again. Some modules have an SVC (service) button that is reserved and should not be pressed in normal operation.

The HIB-IP 8002 adds front-panel LEDs for MCN network RX and TX, an Ethernet link and activity indicator, and a WINK LED that blinks when a wink command is sent from the MCN software (useful to identify a unit); on it a solid ERR LED means low voltage on the DC input or network input. In configuration mode it can be powered from its USB port, in which case a solid ERR LED is acceptable.

Problems and checks

Symptom Checks
PWR LED off Check that the power supply is plugged into the module's DC IN port and into the wall. If power comes over the network cable, check the cable connections between NETWORK OUT and NETWORK IN ports
PWR LED blinking Low voltage. Plug a supply directly into the module's DC IN and see whether blinking stops; if so, check that the system's power distribution limits are met (four modules per supply, 100 feet between them)
ERR LED blinking or on Reset the module; if it still blinks, call CTI customer support. Verify that the Group and Module numbers are valid (Group FF is not allowed) and press reset. Verify the option switches
ACT LED off Verify Group and Module numbers and press reset; verify option switches; check that network cables are fully seated; check that terminators are installed at both ends of the network
Status not displayed correctly (VOTE, RECEIVE, DISABLE or FAIL), or FORCE VOTE or DISABLE does not work Verify all wiring between the comparator I/O module and the comparator, and between the user-interface module and the operator station; verify all unit addresses; verify option switches on all modules; verify that total network cable length and the number of modules are within the limits (1200 feet and 20 modules per segment)

If the table does not solve the problem, the module's own hardware manual may have more specific troubleshooting steps, and CTI's engineers can be reached by phone; have the module's name, model number and serial number ready.

Console LED caution

Console DISABLE and VOTE lines are bidirectional, so a console LED may show a disable that never reached the comparator (the network is not connected, or the receiver is force-voted and the comparator ignores the disable). Confirm the comparator state from a PC display before trusting a console LED (mcn-monitoring-and-control-network-overview).

Software-level checks

For IP-connected systems see the status and fail causes in mcn-server-8000-and-ip-modules, and for detecting receivers that silently stop receiving or voting, see mcn-system-performance-toolkit.

Source documents

This article summarizes the following published CTI Products manuals. They are the authoritative reference.

This article is part of the CTI Products Knowledge Base. Questions about RadioPro or MCN products? Call +1 (513) 595-5900 or email info@ctiproducts.com.

Informational only. This article is general background and is not engineering, safety, legal or regulatory advice. Verify requirements with the equipment manufacturer and the applicable authority before relying on it. Product names and trademarks belong to their respective owners.