Electronics Fundamentals: Decibels (dB, dBm, dBi)

Two-Way Radio Concepts and Electronics Fundamentals · Last updated · About 3 min read

The decibel (dB) is the unit radio work runs on. It expresses ratios logarithmically, which turns the multiplication of gains and losses along a signal path into simple addition — the entire link budget discipline is dB arithmetic.

The Core Definition

For power: dB = 10 × log₁₀(P₂ / P₁). For voltage (same impedance): dB = 20 × log₁₀(V₂/V₁).

Decibels as a power ratio, and why they add along a signal path A curve of power ratio against decibels on a logarithmic scale: minus 3 dB is half the power, plus 3 dB is double, plus 6 dB is four times, plus 10 dB is ten times, plus 20 dB is a hundred times and plus 30 dB is a thousand times. Beside it, a transmitter at 10 watts or 40 dBm loses 3 dB in the feedline and gains 9 dB at the antenna, giving 46 dBm or about 40 watts radiated, because 40 minus 3 plus 9 is 46. Adding decibels multiplies the powerThe curve is 10^(dB/10) — every 10 dB is another ten times the power×1×10×100×1000-30-20-100+10+20+30decibels−3 dB = half+3 dB = double+10 dB = ×10+20 dB = ×100+30 dB = ×1000Why dB is worth the troubleAlong a path, gains and losses add instead of multiplyingTransmitter10 W40 dBmFeedline losshalf the power−3 dBAntenna gain×8+9 dBiRadiated (EIRP)about 40 W46 dBm40 − 3 + 9 = 46— arithmetic, not multiplicationThat is the whole reason radio work is done in dB: a chain of multiplications and divisions becomes acolumn of numbers you can add in your head.
Only the first column needs a calculator. Once a path is written in dB, the rest is addition.

The numbers worth memorizing:

dB Power ratio Mental shorthand
+3 dB ×2 double the power
−3 dB ×0.5 half the power
+6 dB ×4 double the voltage
+10 dB ×10 order of magnitude
+20 dB ×100 two orders
+30 dB ×1000 three orders
0 dB ×1 no change

Combinations follow instantly: +13 dB = 10 + 3 → ×20. A 6 dB feedline loss means only a quarter of the transmitter power reaches the antenna.

Absolute Units: dB Referenced to Something

Plain dB is a ratio. Add a suffix and it becomes an absolute level against a stated reference:

  • dBm — power relative to 1 milliwatt. The universal RF power unit: 0 dBm = 1 mW, +30 dBm = 1 W, +50 dBm = 100 W. Receiver signal levels are tiny: a typical LMR receiver hears down to about −119 dBm (~0.25 µV), and RSSI readings are quoted in dBm (−70 dBm strong, −110 dBm marginal).
  • dBW — relative to 1 watt (30 dB above dBm).
  • dBµV — voltage relative to 1 microvolt, common on signal generators and older receiver specs (in a 50 Ω system, 0 dBµV ≈ −107 dBm).
  • dBi / dBd — antenna gain relative to an isotropic radiator (dBi) or a dipole (dBd). dBi = dBd + 2.15. Marketing prefers dBi because the number is bigger; compare like to like.
  • dBc — relative to the carrier; used for spurious emissions and phase noise.
  • dB SPL — sound pressure level, the acoustic cousin encountered in microphone and speaker specs.

Rule of thumb: you can add dB to dBm (gain/loss applied to a level), but adding dBm to dBm is meaningless — two absolute powers don't add that way.

A Worked Radio Example

Repeater transmitter +47 dBm (50 W) → duplexer −1.5 dB → 200 ft of feedline −2 dB → antenna +6 dBd:

47 − 1.5 − 2 + 6 (dBd) = +49.5 dBm effective radiated power (ERP ≈ 90 W)

Why Logarithms Fit Radio

Radio signal levels span absurd ranges — a 100 W transmitter is +50 dBm and a just-readable signal is −119 dBm: 17 orders of magnitude. Logarithmic units compress that range into two- and three-digit numbers, and they match human perception too (hearing is roughly logarithmic, which is why audio levels also use dB).

Practical Cautions

  • Keep power dB (10 log) and voltage dB (20 log) straight; test equipment usually reports power dB.
  • Watch references: a "−10 dB" spec means nothing until you know −10 dB relative to what.
  • Small dB numbers matter at the margins: 3 dB of extra feedline loss is half the effective coverage power, and 1–2 dB of receiver degradation (desense) can erase a system's fade margin.

This article is part of the CTI Products Knowledge Base. Questions about RadioPro or MCN products? Call +1 (513) 595-5900 or email info@ctiproducts.com.

Informational only. This article is general background and is not engineering, safety, legal or regulatory advice. Verify requirements with the equipment manufacturer and the applicable authority before relying on it. Product names and trademarks belong to their respective owners.