RadioPro Dispatch Voice Dispatching, Audio Levels and Emergencies
How a RadioPro Dispatch operator makes and receives calls, sets Select/Unselect and microphone levels, patches talk groups and handles emergencies.
This article describes how voice works in RadioPro Dispatch. Each connected control-station radio appears on a Voice tab as a Radio Controller (a virtual radio panel). The system administrator decides which panels, buttons and tabs a console shows, and some features depend on the license and on the radio system type (radiopro-dispatch-feature-availability-by-system-type).
Making a call
- Group call to a talk group: click and hold the PTT button on a Radio Controller while speaking. On a touch screen, touch and hold. A PTT pushbutton on a desk microphone or a footswitch can be configured to key a particular talk group.
- Private call to one subscriber: select the subscriber in the Subscribers panel (or on the map) and hold the PTT at the bottom of that panel. See radiopro-dispatch-subscribers-contacts-and-messaging.
- Call Selected: a toolbar button can call one or more selected talk groups. Click the header of a Radio Controller to select it (the header turns yellow); hold Ctrl and click other headers to select several.
- All Call: a toolbar button can call every subscriber in the radio system. All Call voice is queued in memory and sent when the channel is clear, so every subscriber receives the entire message.
- All Emergency: a toolbar button can activate the emergency tone on every radio in the system.
While transmitting, the PTT button turns red, a transmitting icon appears, and the panel shows the Radio ID or Group ID with its alias name and whether the call is private or group.
Receiving a call
When the control-station radio decodes a valid call, the Radio Controller shows a receiving icon, whether it is a private or group call, and the ID and alias of the caller. The audio plays through the PC speakers at the Selected or Unselected volume, depending on whether that panel is the selected one. The panel also distinguishes a call that came from an IP client (another RadioPro client) from one that came from an RF subscriber.
Audio levels
The toolbar has a microphone (transmit) slider with a VU meter, a Select slider and an Unselect slider. Only one gateway is "selected" at a time, shown by a yellow title bar. Select sets the volume of audio from the selected Radio Controller; Unselect sets the volume of all the others, so a dispatcher can keep background talk groups quieter than the one being worked.
The guide's recommended starting point:
- Mic and Select sliders at 100% and Unselect at 50%.
- The speaker tool in each Radio Controller at 100%.
- If desk speakers are used, set their own volume knob to about 50%.
- Watch the VU meter while speaking: the level should reach into the yellow region 10 to 50% of the time. Red means clipping and distortion and should be avoided.
Microphone and speaker choices are stored in Audio Presets (Options menu), which the administrator defines for each kind of speaker, microphone or headset. Only one input device is active at a time. If a wider range is needed, the Windows recording and playback levels can be adjusted by the administrator. See audio-levels-and-radio-interfacing for general background on audio levels.
Diagnosing a volume problem
In the Recent History panel, selecting an incoming voice event shows its volume as a percentage, and the Volume Info button breaks the total call volume into its components: the per-radio resource volume, the Select or Unselect volume, and (for audio from another Dispatch client) the Intercom volume. The total is the aggregate of all of them. See radiopro-dispatch-history-logging-and-archive-viewer.
Patching
If the administrator has enabled it, a Patch button appears on the Radio Controller header. Clicking the button on two Radio Controllers patches the two talk groups together: voice traffic in both directions is shared, and a call placed by the dispatcher to either is heard on both. Patching is limited to a single pair of talk groups for the whole RadioPro system, and patch status is displayed on other Dispatch clients that have the option enabled. A patch can also join two radio systems of different brands, such as MOTOTRBO and NEXEDGE, but only the audio crosses (radiopro-bridging-two-radio-systems). For general background see cross-patching-and-system-bridging.
Connection status
- Radio connected: the panel shows the gateway name and the configured buttons.
- Radio Disconnected: the gateway cannot talk to its control-station radio; the panel is shaded dark gray.
- Can't connect to Gateway: the Dispatch client cannot reach the IP Gateway; the panel is shaded dark gray.
See radiopro-dispatch-troubleshooting.
Emergencies
When a subscriber sends an emergency:
- An Emergency Notification Tool appears on the main toolbar.
- A red emergency icon appears next to the subscriber in the Subscribers panel.
- An audio alarm sounds.
The top part of the Emergency Notification Tool acts as a PTT: it silences the alarm and places a private call back to the radio that sent the emergency. The bottom part removes the visual and audible indicators. The administrator chooses how the emergency state in the control-station radio itself is cleared: either when the emergency is removed from the drop-down, or by restarting the radio (Options, Manage IP Gateways, right-click the radio, Restart Radio). General background: emergency-man-down-alerts.
Toolbar custom buttons and disk caution
Toolbar buttons can be defined for many actions and carry custom labels. The toolbar also shows a caution symbol when fewer than two weeks of storage remain on the disk partition used for logging; if the partition fills, logging stops until the administrator frees space.
Source documents
This article summarizes the following published CTI Products manuals. They are the authoritative reference.
See also: CTI product documentation
This article is part of the CTI Products Knowledge Base. Questions about RadioPro or MCN products? Call +1 (513) 595-5900 or email info@ctiproducts.com.
Informational only. This article is general background and is not engineering, safety, legal or regulatory advice. Verify requirements with the equipment manufacturer and the applicable authority before relying on it. Product names and trademarks belong to their respective owners.